Control Reference Guide: I/O Connectors
19
Control Reference Guide
15.PARALLEL REMOTE connector
This is a 15-pin parallel remote connector.
The assignment for each port can be selected in the “PAR-
ALLEL PORT PORT1-7 PORT 9-14” ( page 100 and
page 101) menu item.
Note:
Supply TTL-level, active LOW electrical signals with an edge
of 100 msec or higher as input signals.
A maximum open collector and sink current of 6 mA is out-
put as an output signal.
Use a shielded cable to connect to this connector.
16.Fan
This fan is for cooling the unit. Install the unit where the
ventilation holes will not be blocked.
Note:
If the fan is stopped while the power is on, the “FAN
STOPPED” warning is displayed. The unit will operate even if
the fan is stopped. However, please stop using the unit imme-
diately.
Pin
No.
Port Name Function
1 PORT1 Command input port 1
2 PORT2 Command input port 2
3 PORT3 Command input port 3
4 PORT4 Command input port 4
5 PORT5 Command input port 5
6 PORT6 Command input port 6
7 PORT7 Command input port 7
8 +5 V Output
(+180 mA max.)
9 PORT9 Status output port 1
10 PORT10 Status output port 2
11 PORT11 Status output port 3
12 PORT12 Status output port 4
13 PORT13 Status output port 5
14 PORT14 Status output port 6
15 GND GND
12345678