27
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Model code for mono-bloc units
Device type
WH:   Air-to-water 
heat pump
Construction M: Mono-bloc outdoor unit
Series
D: Aquarea High Performance, X: Aquarea T-CAP,  
H: Aquarea HT
Operating mode
 1
C: Heating and cooling, F: Heating only
Nominal  
heating capacity
 2
05 to 16 (corresponds to 5 to 16 kW)
Device 
generation
 3
... G, H, J ...
Backup heater  
capacity
3: 3 kW, 6: 6 kW, 9: 9 kW
Market E: Europe
Power supply 5: Single phase, 8: Three phase
WH ‑ M D C 09 J 3 E 5
1  The devices of the Aquarea HT series can only be used for heating mode and have no cooling function.
2  The available capacities dier according to the series. An overview is given in the model range (→ 1 Model range, 
p. 8).
3  J generation requires refrigerant R32, H generation requires refrigerant R410A, F generation requires refrigerant R407C.
4.6  Functions and technical data
4.6.1  Product features
Energy eciency and environment friendliness
 ● Up to 80 % of the energy is obtained from the ambient air for greater energy eciency
 ● COP of 5.33 for the single phase 3 kW bi-bloc and All in One systems or COP of 
5.08 for the single-phase 5 kW mono-bloc system for A7 / W35 (all High Performance 
series, J Generation)
 ● Inverter technology allows for a demand-controlled power output of the device and 
thus contributes to energy savings
 ● Environmentally friendly refrigerants (R32 and R410A for Aquarea High Performance 
and T-CAP, R407C for Aquarea HT)
 ● All systems are tted with a high-eciency pump
High Comfort
 ● Optimum control
 ● Models available for heating only (HT) or for heating and cooling (High Performance 
and T-CAP)
 ● Optimised performance based on return water temperature
 ● Integrated control of the hot water tank and heating
 ● 24-hours timer with mode control
 ● Model WH-ADC0309J3E5B complete with all necessary equipment for control of two 
individual heating zones
 ● Extremely compact model WH-ADC0309J3E5C optimised for combination with 
optional Heat recovery Ventilation Unit (HRV)