EasyManua.ls Logo

Panasonic Aquarea WH-UD09JE5-1 - Example 4: Bivalent Two-Zone System with Buffer Tank

Panasonic Aquarea WH-UD09JE5-1
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
140 Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Planning
5
5.6.4 Example 4: Bivalent two-zone system with bu󰀨er tank
Hydrokit, T-CAP, 9 kW, second heat source, domestic ot water tank, 2 heating zones
WH-Ux09HE8 [9 kW]
Ø15,88
Ø 9,52
WH-SxC09H3E8
[9 kW]
H3
H2
H1
CZ-NS4P
H12 [E39]
T
PAW-A2W-TSOD [E36]
H4
PAW-TA30C2E5STD
H24
H23
H22
H21
H10
H5
H7
H25 [E28]
H6
RT1
H11
H13[E51]
H14[E59]
H14 [E58]
H9 [E53]
H13[E52]
PAW-A2W-TSHC [E45]
PAW-A2W-TSHC [E44]
H11
RT2
H9 [E54]
PAW-A2W-TSBU [E42]
M
M
M
H15[E32]
NL
N
L
A3LA2LA1
NL
5
4
3
21
E61
E63
E60
E62
C
PAW-A2W-TSOD
O N C O N C N LH
CZ-TK1
AC 230 V
E27
E28
E30
E33
E34
E35
E36
E38
AC 230 V
PAW-A2W-TSHC
PAW-A2W-TSHC
PAW-A2W-TSBU
PAW-A2W-TSRT
AC 230 V
N O C N O C
AC 230 V
N C HLN C HL
PAW-A2W-TSRT
E40
E41
E42
E44
E45
E46
E48
E49
E50
E51
E52
E53
E54
E57
E58
E59
E32
CZ-NS4P
E39
E26

Table of Contents