Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Bi-bloc systems | Aquarea HT | F Generation | Single Phase / Three Phase | Heating Only | R407C
Single phase (Power to indoor) Three phase (Power to indoor)
Kit KIT‑WHF09F3E5 KIT‑WHF12F6E5 KIT‑WHF09F3E8 KIT‑WHF12F9E8
Heating capacity / COP (A +7 °C, W 35 °C) kW / COP 9,00 / 4,64 12,00 / 4,46 9,00 / 4,64 12,00 / 4,46
Heating capacity / COP (A +7 °C, W 65 °C) kW / COP 9,00 / 2,48 12,00 / 2,41 9,00 / 2,48 12,00 / 2,41
Heating capacity / COP (A +2 °C, W 35 °C) kW / COP 9,00 / 3,45 12,00 / 3,26 9,00 / 3,45 12,00 / 3,26
Heating capacity / COP (A +2 °C, W 65 °C) kW / COP 9,00 / 2,06 10,30 / 2,01 9,00 / 2,06 10,30 / 2,01
Heating capacity / COP (A -7 °C, W 35 °C) kW / COP 9,00 / 2,74 12,00 / 2,52 9,00 / 2,74 12,00 / 2,52
Heating capacity / COP (A -7 °C, W 65 °C) kW / COP 9,00 / 1,79 9,60 / 1,77 9,00 / 1,79 9,60 / 1,77
ErP data for Space Heating
Average climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 153 / 125 150 / 125 153 / 125 150 / 125
SCOP W35 / W55 3,90 / 3,20 3,82 / 3,21 3,90 / 3,20 3,82 / 3,21
Energy class
1
W35 / W55 A++ / A++ A++ / A++ A++ / A++ A++ / A++
Warm climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 191 / 156 188 / 156 191 / 156 188 / 156
SCOP W35 / W55 4,84 / 3,97 4,77 / 3,97 4,84 / 3,97 4,77 / 3,97
Energy class
1
W35 / W55 A+++ / A+++ A+++ / A+++ A+++ / A+++ A+++ / A+++
Cold climate
Seasonalenergyefciency(ηs,h) W35 / W55 % 137 / 116 134 / 113 137 / 116 134 / 113
SCOP W35 / W55 3,50 / 2,97 3,42 / 2,90 3,50 / 2,97 3,42 / 2,90
Energy class
1
W35 / W55 A+ / A+ A+ / A+ A+ / A+ A+ / A+
Indoor unit
WH‑SHF09F3E5
WH‑SHF12F6E5 WH‑SHF09F3E8 WH‑SHF12F9E8
Sound pressure dB(A) 33 33 33 33
Dimension H x W x D mm 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353 892 x 502 x 353
Net weight kg 46 47 47 48
Water pipe connector Inch R 1¼ R 1¼ R 1¼ R 1¼
A class pump
Number of speeds 7 7 7 7
Input power (Min / Max) W 38 / 100 40 / 106 38 / 100 40 / 106
Heatingwaterow(∆T=5K.35°C) L/min 25,8 34,4 25,8 34,4
Capacity of integrated electric heater kW 3 6 3 9
Recommended fuse A 30 / 30 30 / 30 30 / 16 30 / 16
Recommended cable size, supply 1 / 2 mm² 3 x 4,0 or 6,0 / 3 x 4,0 3 x 4,0 or 6,0 / 3 x 4,0 5 x 1,5 / 3 x 1,5 5 x 1,5 / 5 x 1,5
Outdoor unit WH‑UH09FE5 WH‑UH12FE5 WH‑UH09FE8 WH‑UH12FE8
Sound power
1)
dB(A)
Dimension H x W x D mm 1 340 x 900 x 320 1 340 x 900 x 320 1 340 x 900 x 320 1 340 x 900 x 320
Net weight kg 104 104 110 110
Refrigerant (R407C) / CO
2
Eq. kg / T 2,90 / 5,145 2,90 / 5,145 2,90 / 5,145 2,90 / 5,145
Pipe diameter Liquid / Gas Inch (mm) 3/8 (9,52) / 5/8 (15,88) 3/8 (9,52) / 5/8 (15,88) 3/8 (9,52) / 5/8 (15,88) 3/8 (9,52) / 5/8 (15,88)
Pipe length range m 3 ~ 30 3 ~ 30 3 ~ 30 3 ~ 30
Elevation difference (in/out) m 20 20 20 20
Pipe length for additional gas m 10 10 10 10
Additional gas amount g/m 70 70 70 70
Operation range
Outdoor ambient Heat °C -20 ~ +35 -20 ~ +35 -20 ~ +35 -20 ~ +35
Water outlet Heat °C 25 ~ 65 25 ~ 65 25 ~ 65 25 ~ 65
1 Scale from A+++ to D.
2 Sound power in accordance to 811/2013, 813/2013 and EN12102-1:2017 at +7 °C.
Note:
EER and COP calculation is based in accordance to EN14511.
4.6.3 Mono-bloc system
The mono-bloc system consists of one single unit that is installed outdoors and can be connected
directly to the heating circuit. The operation is e󰀨ected via wired remote controller inside the
building.