EasyManua.ls Logo

Panasonic Aquarea WH-UD09JE5-1 - Recommended On-Site Accessories

Panasonic Aquarea WH-UD09JE5-1
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90 Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Heat recovery Ventilation unit PAW-A2W-VENTA-L PAW-A2W-VENTA-R
Duct connections mm DN125
Filter class, supply air F7/ePM1 60 %
Filter class, exhaust air M5/ePM10 50 %
Minimum outdoor temperature °C -20
1) Heat recovery e󰀩ciency according to EN 13141-7.
Note:
Heat recovery Ventilation unit is produced by Systemair.
4.8.5 Recommended on-site accessories
Panasonic recommends the following on-site accessories It is particularly advisable to use building
components and accessories recommended by the manufacturer. Use the correct interfaces
(→ 4.7.2 External interfaces (inputs/outputs), p. 65) and connection conditions when connecting
the accessories.
Overview of the specications of the recommended on-site accessories
Construction / Indoor unit type Bi‑bloc systems Mono‑
bloc
systems
with All in One
unit
with
hydrokit
Device generation J / H F J / H G J / H
Model type (conguration) B C
No. Component
Quan‑
tity
Description Model
Power
supply
Make
A 2-way valve set 1
Electrical motor actuator SFA21/18 230 V AC
Siemens
2
2
2
2
2
2
2
2-way valve VVI46/25
B 3-way valve set 2
Electrical motor actuator SFA21/18 230 V AC
Siemens
3-way valve VXI46/25
C Room thermostat 1
Analogue RAA20
230 V AC Siemens
Programmable REV200
D Room thermostat 1
Wired PAW-A2W-RTWIRED 230 V AC
1
Wireless PAW-A2W-RTWIRELESS 230 V AC
1
E Mixing valve 1 167032 230 V AC Calef ³
F Pump 1 Yonos 25/6 230 V AC Wilo ³
G Temperature sensor for buffer tank 1 PAW-A2W-TSBU
1
³
H Outdoor temperature sensor 1 PAW-A2W-TSOD
1
³
I
Inowtemperaturesensorfor
heating circuit
1 PAW-A2W-TSHC
1
³
J Room temperature sensor 1 PAW-A2W-TSRT
1
³
K Solar sensor 1 PAW-A2W-TSSO
1
³
L
Base pan heater for outdoor/
mono-bloc units
1
Only for models with
3 or 5 kW
CZ-NE2P Panasonic
M
Base pan heater for outdoor/
mono-bloc units
1
For all models after
the F generation with
> 5 kW
CZ-NE3P Panasonic
N
Additional PCB for expanded
controller functionality
1 CZ-NS4P Panasonic ³
O
Interface for the control over the
Internet via Aquarea Smart Cloud
1 CZ-TAW1 Panasonic
P
10 m extension cable for
CZ-TAW1
CZ-TAW1-CBL Panasonic
1 To be sourced through Panasonic
2 Only for unlocked cooling mode
3 Already installed at the time of dispatch
We recommend that the client-provided accessories be sourced from the manufacturers named in the table.

Table of Contents

Related product manuals