EasyManua.ls Logo

Panasonic Aquarea WH-UD09JE5-1 - Functions and Technical Data; Product Features

Panasonic Aquarea WH-UD09JE5-1
224 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Product Description
4
Model code for mono-bloc units
Device type
WH: Air-to-water
heat pump
Construction M: Mono-bloc outdoor unit
Series
D: Aquarea High Performance, X: Aquarea T-CAP,
H: Aquarea HT
Operating mode
1
C: Heating and cooling, F: Heating only
Nominal
heating capacity
2
05 to 16 (corresponds to 5 to 16 kW)
Device
generation
3
... G, H, J ...
Backup heater
capacity
3: 3 kW, 6: 6 kW, 9: 9 kW
Market E: Europe
Power supply 5: Single phase, 8: Three phase
WH M D C 09 J 3 E 5
1 The devices of the Aquarea HT series can only be used for heating mode and have no cooling function.
2 The available capacities di󰀨er according to the series. An overview is given in the model range (→ 1 Model range,
p. 8).
3 J generation requires refrigerant R32, H generation requires refrigerant R410A, F generation requires refrigerant R407C.
4.6 Functions and technical data
4.6.1 Product features
Energy e󰀩ciency and environment friendliness
Up to 80 % of the energy is obtained from the ambient air for greater energy e󰀩ciency
COP of 5.33 for the single phase 3 kW bi-bloc and All in One systems or COP of
5.08 for the single-phase 5 kW mono-bloc system for A7 / W35 (all High Performance
series, J Generation)
Inverter technology allows for a demand-controlled power output of the device and
thus contributes to energy savings
Environmentally friendly refrigerants (R32 and R410A for Aquarea High Performance
and T-CAP, R407C for Aquarea HT)
All systems are tted with a high-e󰀩ciency pump
High Comfort
Optimum control
Models available for heating only (HT) or for heating and cooling (High Performance
and T-CAP)
Optimised performance based on return water temperature
Integrated control of the hot water tank and heating
24-hours timer with mode control
Model WH-ADC0309J3E5B complete with all necessary equipment for control of two
individual heating zones
Extremely compact model WH-ADC0309J3E5C optimised for combination with
optional Heat recovery Ventilation Unit (HRV)

Table of Contents