168 Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Installation
6
Connections of the water pipes – All in One unit | J and H generation | Compact
conguration (for 1 heating zone)
WH-ADC0309J3E5C, WH-ADC1216H6E5C
a b c d
a Supply water outlet (to space heating/cooling)
b Return water inlet (from space heating/cooling)
c Fresh water inlet
d Supply water outlet (to hot water tank)
Connections of the water pipes – All in One unit | H generation | Standard conguration (for
1 heating zone)
WH-ADC1216H6E5, WH-ADC0916H9E8
dcba
a Supply water outlet (to hot water tank)
b Fresh water inlet
c Supply water outlet (to space heating/cooling)
d Return water inlet (from space heating/cooling)

Table of Contents