EasyManua.ls Logo

Panasonic BT-H1700P

Panasonic BT-H1700P
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
Adjustment Signal Function
Adjustment Data
RG B
COMMON
Drive WO01 WO03
Cut off WO04 WO05 WO06
1080/60i
Drive WI01 WI03
(Common to 1080/24psf)
Cut off WI04 WI05 WI06
720/60p
Drive WK01 WK03
Cut off WK04 WK05 WK06
480/60i
Drive WE01 WE03
(Common to 576/50i)
Cut off WE04 WE05 WE06
480/60p
Drive WG01 WG03
(Common to 576/50p)
Cut off WG04 WG05 WG06
COMPONENT SIGNAL HIGH-LIGHT WHITE BALANCE ADJUSTMENTS (HIGH: D9300)
Measuring Instruments Signal generator (Component 10-step gray scale signal)
Color temperature meter
Card (Slot) Component/RGB Input Card (Slot 1)
Test Points
Adjustment Points W*01 (Drive (R)), W*03 (Drive (B)), W*04 (Cut Off (R)),
W*05 (Cut Off (G)), W*06 (Cut Off (B)) [Service Menu]
Notes: Perform the following adjustments after completing the Low-Light White Balance Adjustment.
Set the COLOR TEM./BAL. data in the Setup Menu to 00.
The values adjusted with WO become the reference values for the following adjustment. When this data is changed, it is required
to re-adjust the white balance data of all of the adjustment signals (Component, NTSC and PAL).
When re-adjusting the 1080/60i signal, use the WI.
1. Apply the 1080/60i component 10-step gray scale signal to INPUT A.
2. Set COLOR TEMP. of COLOR TEMP./BAL. in the Setup Menu to HIGH.
3. Set the PHASE, CHROMA, BRIGHT and CONTRAST potentiometers on the front panel to the center click positions.
4. Adjust WO01 and WO03 in the Service Menu using the color temperature meter so that the color temperature is set as shown below.
(Do not touch WO02.)
Color temperature : HIGH (D9300). x = 0.283, y = 0.297 (Reference value)
5. Ensure that the white balance tracking is correct from the gray scale steps with lower color temperatures to those with higher color temperatures.
If the white balance tracking is deviated in darker steps, adjust WO04 to WO06 (Low-Light) to correct it.
(Do not set the values of WO04 to WO06 no more than 50.)
6. Vary the adjustment signal and adjustment data, and re-perform adjustments in steps 1 to 5 above (see Table 18).
SIGNAL WHITE BALANCE ADJUSTMENTS
Table 18

Table of Contents

Related product manuals