EasyManua.ls Logo

Panasonic BT-H1700P

Panasonic BT-H1700P
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
CONTRAST ADJUSTMENT (HDTV)
Notes: Perform the following adjustments after completing the
Screen Voltage adjustment.
Set the CONTRAST data in the Setup Menu to 00.
The value adjusted at the SO adjustment becomes the
reference value for the following adjustments. When this
data is changed, it is required to re-adjust the data of all
of the adjustment signals (HDTV, SDTV and NTSC/PAL).
When re-adjusting the 1080/60i signal, use the SI.
When overscan data of a signal is changed, it is required
to re-adjust the underscan data of the same adjustment
signal.
Standard value (SO) adjustment
1. Apply the 1080/60i crosshatch signal to INPUT A (Terminal Y on the
Component/RGB Input Card).
2. Set the CONTRAST potentiometer on the front panel to the center
click position.
3. Connect the oscilloscope across TP-47G and TP-GND.
4. Adjust SO01 in the Service Menu to set the voltage amplitude <A>
in the figure on the right to 30 V ± 2 V.
Other signals adjustments
5. Apply the 1080/60i crosshatch signal to INPUT A (Terminal Y on the
Component/RGB Input Card).
6. Set the CONTRAST potentiometer on the front panel to the center
click position.
7. Connect the oscilloscope across TP-47G and TP-GND.
8. Adjust SI01 in the Service Menu to set the voltage amplitude <A> in
the figure on the right to 30 V ± 2 V.
9. Set the UNDER SCAN button on the front panel to ON so that the
scanning size is set to underscanning.
10. Adjust SM25 to set the voltage amplitude <A> to 30 V ± 2 V.
11. Press the UNDER SCAN button on the front panel to set the
underscan to OFF.
12. Vary the adjustment signal and adjustment data, and re-perform
adjustments in steps 5 to 11 above (see Table 1).
SIGNAL CONTRAST ADJUSTMENTS
1 Vertical interval
(V. sync)
<A>
30V ± 2V
Adjustment Signal Scanning Size Adjustment Data
COMMON
Overscan SO01
Underscan
1080/60i
Overscan SI01
Underscan SM25
1080/24pSF
Overscan SJ01
Underscan SM28
720/60p
Overscan SK01
Underscan SM31
Table 1
Measuring Instruments Signal generator (Crosshatch signal)
Oscilloscope
Card (Slot) Component/RGB Input Card (Slot 1)
Test Points TP-47G [CRT SOCKET PWB]
TP-GND [CRT SOCKET PWB]
Adjustment Points S*01 (Overscan Contrast), SM** (Underscan Contrast) [Service Menu]

Table of Contents