– 20 –
MAC9512086C2
CS-A181KR
Operation Details
Cooling
Soft Dry
Heating
* Automatic Set Temperature
Refer c) as below.
23°C
20°C
Intake
Air
Temperature
Present
Mode
Cooling
Soft Dry
Heating
Judgement
23°C Cooling
Heating
20°C Soft Dry
Heating
Cooling
25°C Heating
Cooling
O
(Judgement :
23°C & Above)
Not Applicable
O
(Judgement :
25°C & Above)
Next Mode
Soft Dry
Not Applicable
O
(Judgement :
20°C & Above)
Not Applicable
Heating
O
(Judgement :
Below 23°C)
O
(Judgement :
Below 20°C)
O
(Judgement :
Below 25°C)
* Automatic Set Temperature Refer c) as below.
c) Automatic Set Temperature
For each operation, set temperature will automatically set as shown below.
However it can be selected 2°C higher or 2°C lower from standard set temperature by pressing the “Room
Temperature Setting button”.
Standard
(±0°C)
25°C
22°C
21°C
Lower
(–2°C)
23°C
20°C
19°C
Operation
Mode
Cooling
Soft Dry
Heating
Higher
(+2°C)
27°C
24°C
23°C
Standard for Determining Operation Mode 2nd Judgement onwards
Standard for Determining Operation Mode 1st Judgement
4) Automatic Mode Operation
a) When the Automatic Mode Operation is selected, the indoor fan operates at SLo fan speed for 20 second to sense
intake air temperature and determine the 1st operation mode.
b) Operation mode will be determine again after 1hour of operation, if the room temperature reaches to set
temperature and compressor off time is over 7 minutes 30 seconds continuously.
* Indoor intake air is less than 16°C, Heating mode will immediate operate.
* The present operation mode will be continued, if the room temperature does not reach to set temperature
(Compressor keeps running) eventhough after 1 hour from automatic operation mode started.
For 2nd judgement onwards, indoor fan will operate for 25 seconds to sense the intake air temperature for
determining operation mode.
b) Overload Deicing Time Diagram
Outdoor
Heat
Exchanger
Temp.
12°C
Tb
-3°C
-4°C
abcdef ghi j kl mnopqr
Basic Time
Compressor
4-way Valve
Indoor Fan
Outdoor Fan
Operation LED
60'
10" 20"
Max
12'
Max
4'
60'
: Blinking
Operation
Stop
<Description of operation>
a – i : Overload control.
i – l : Overload deicing.
l – m : Hot start (add 4 min delay timing).
m – r : Overload control.
Untitled-2 6/10/00, 9:31 AM20