EasyManuals Logo

Panasonic CS-A181KR User Manual

Panasonic CS-A181KR
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
– 4 –
MAC9512086C2
CS-A181KR
Outdoor Unit
Functions
4-Way Valve Control
When the unit is switched to "OFF" during
Heating operation, 4-way valve stays at
Heating Position for 5 minutes.
60 Secs. Forced Operation Control
Once the compressor is activated, it does
not stop for 60 secs. (Stops immediately
with remote control stop signal.)
Outdoor Fan Operation Control
4-pole induction motor (2-speed)
For Cooling or Soft Dry Operation
Hi-speed … when outdoor temperature
reaches to 31°C
Lo-speed … when outdoor temperature
reaches to 29°C
For Heating Operation
Hi-speed ... when outdoor temperature
reaches to 13.5°C.
Lo-speed ... when outdoor temperature
reaches to 15.5°C.
For Over-heating Protection, the Fan is
switched ON or OFF depending on the
piping temperature and the outdoor tem-
perature.
Overload Protector
Inner protector (Compressor, Fan Motor).
Deice Control
To prevent frosting at outdoor heat
exchanger during Heating Operation.
2-Way Valve Control
2-way valve is ON for 1 minutes after
compressor start. Other than this, 2-way
valve is OFF. (A241K only)
Untitled-1 6/10/00, 9:27 AM4