ENGLISH
22
• Is the discharge air cold
(warm)?
Operation is normal if, 15
minutes after the start of
operation, the temperature
difference between the air
intake and outlet vents is 8°C
or above for cooling and 14°C
or above for heating.
• Are the remote control batteries weak?
If the remote control display appears weak, replace the
batteries (page 12).
● Pre-season Inspection
• Are the air intake or outlet
vents of the indoor or
outdoor units obstructed?
●
When the Air Conditioner is Not Used For an Extended
Period of Time
1To dry the internal parts of the indoor unit, operate
the unit for 2 - 3 hours using operation with
30°C setting temperature.
2Turn off the power switch and remove the power
supply plug.
Note:If the unit is not switched off by the remote
control, it will start operating when you plug in
(because a Auto Restart Control is provided).
3Remove the remote control batteries.
• The unit will become dirty after use over several seasons, reducing performance.
Depending on the operation condition, a dirty unit may produce foul odours and dust may pollute the
dehumidifying drainage.
Seasonal inspection is recommended, in addition to regular cleaning. Consult an authorized dealer.
● Recommended Inspection
COOL