13.6. Compressor Reverse Rotation Protection Control
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor
heat exchanger is 2.5qC or less for continuous 2 minutes, compressor will stop and restart automatically.
Time Delay Safety Control is activated before the compressor restart.
This is to prevent compressor from rotate reversely when there is an instantaneous power failure.
13.7. Dew Prevention control
To prevent dew formation at indoor unit discharge area.
This control start if:-
- Cooling mode or Quiet mode is activated.
- Remote Control setting temperature is less than 25qC.
- Fan speed is at CLo or QLo.
- Room temperature is constant (±1qC) for 30 minutes.
- Compressor is continuously running.
Fan speed and angle of horizontal louver (vertical airflow angle) will be adjusted accordingly in this control.
- Fan speed will be increased slowly if the unit is in quiet mode but no change in normal cooling mode.
- The angle of horizontal louver will be changed as table below:
Dew prevention stop condition.
- Remote control setting temperature is more than 25qC.
- Fan speed is not set to CLo or QLo.
- Select Powerful operation
Operation Mode Airflow direction auto control Airflow direction manual control