13.6. Compressor Reverse Rotation Protection Control
If the compressor is operating continuously for 5 minutes or longer and the temperature difference between intake air and indoor
heat exchanger is 2.5qC or less for continuous 2 minutes, compressor will stop and restart automatically.
Time Delay Safety Control is activated before the compressor restart.
This is to prevent compressor from rotate reversely when there is an instantaneous power failure.
13.7. Dew Prevention control
To prevent dew formation at indoor unit discharge area.
This control start if:-
- Cooling mode or Queit mode is activated.
- Remote Control setting temperature is less than 25qC.
- Fan speed is at Lo or QLo.
- Room temperature is constant (±1qC) for 30 minutes.
- Compressor is continuously running.
Fan speed, angle of horizontal louver (vertical airflow angle) and angle of vertical louver (horizontal airflow angle) will be adjusted
accordingly in this control.
- Fan speed will be increased slowly if the unit is in quiet mode and Lo fan speed.
- The angle of horizontal louver will be changed as table below:
- The angle of vertical louver will be changed as table below:
Dew prevention stop condition.
- Remote Control setting temperature is less than 25qC.
- Fan speed is at Lo or QLo.
- Select Power operation.
Airflow direction auto control Airflow direciton manual control
Airflow direction auto control Airflow direciton manual control

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-C18HKQ and is the answer not in the manual?

Panasonic CS-C18HKQ Specifications

General IconGeneral
BrandPanasonic
ModelCS-C18HKQ
CategoryAir Conditioner
LanguageEnglish

Related product manuals