12.8. Powerful Operation
To achieve the setting temperature quickly.
When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present
setting temperature (Lower temperature limit: 16°C).
This operation automatically will be running under SHi Fan Speed (Cooling).
Vertical Airflow Direction:-
- In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.
- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
Powerful operation stops when:-
- Powerful operation has operate for 15 minutes.
- Powerful mode button is pressed again.
- Stopped by OFF/ON operation button
- Timer OFF activates.
- Quiet mode button is pressed.
- Operation mode is changed.
12.9. Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
To provide quiet cooling operation condition.
Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB (A)
for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present operation sound level.
Manual Fan Speed:-
- RPM control during Lo cool
- RPM control during Hi & Me cool
Auto Fan Speed:-
Quiet operation stops when:-
- Quiet button is pressed again.
- Stopped by OFF/ON operation button.
- Timer OFF activates.
- Powerful button is pressed.