38
- Remote Control Receiving Sound
-Timer Control
- When ON timer activates when unit stops, previous operation resumes and restored last saved patrol operation status.
- When ON timer activates during any operation, no change and carry on current operation.
- When OFF timer activates during any operation, all operation stops and the latest patrol operation status is saved.
- Power Failure Control
- During Patrol individual operation, if power failure occurs, after power resumes, Patrol individual operation resumes
immediately.
- During combination operation, if power failure occurs, after power resumes combination operation resume immediately.
- When e-ion operation is ON during patrol operation if power failure occurs, after power resumes, only patrol operation will
resume but e-ion operation will not resume.
- Power Operation Demo Mode
- Patrol Operation Demo Mode start condition.
• Press “Auto OFF/ON” button at indoor unit for 5 seconds to enter Forced Cooling Operation, then press “Patrol” button
at remote control for 5 seconds and release.
- The Patrol indicator change color every 10 seconds follows the pattern below for demo purpose:
- During demo, all operation stops, remote control buttons and auto OFF/ON button are ignored.
- Patrol Operation Demo Mode stop condition.
• Press “Patrol” button for 5 seconds and release.
• Power supply reset.
- Error Detection Control
- The Patrol error detection control starts once the power is supplied to Patrol sensor. However, the error will display when
the Patrol operation is ON.
- Error detection method:
1. If the Patrol sensor is opened or shorted circuit continuously for 6 hours, Patrol sensor error occurs. However, the error
will display only when the Patrol operation is ON.
- Patrol Sensor Control after error occurs.
1. During any operation mode combines with Patrol operation.
a. Power supply to Patrol sensor is OFF.
b. Air conditioner normal mode operation continues with Patrol LED blinking.
c. The Patrol LED continues blinking if the patrol operation is ON and stops blinking if the Patrol operation is OFF.
- During Patrol individual mode.
1. Power supply to Patrol sensor is OFF.
2. Patrol LED blinks.
3. The Patrol LED continues blinking if the patrol operation is ON and stops blinking if the Patrol operation is OFF.
- Error cancel condition:
1. Power supply reset.
• Normal Operation → Patrol Mode
: Beep
•
Patrol Mode → Stop
: Long Beep
•
Patrol Mode → Normal Operation
: Beep
•
Stop → Patrol
: Beep