6
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb)
and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb)
2. Specifications are subjected to change without prior notice for further improvement.
Piping
Pipe Diameter (Liquid / Gas) mm (inch) 6.35 (1/4) / 12.70 (1/2) 6.35 (1/4) / 15.88 (5/8)
Standard Length m (ft) 5.0 (16.4) 5.0 (16.4)
Length Range (min - max) m (ft) 3 (9.8) ~ 25 (82.0) 3 (9.8) ~ 25 (82.0)
I/D & O/D Height Different m (ft) 20 (65.6) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 20 (0.2) 30 (0.3)
Length for Additional Gas m (ft) 7.5 (24.6) 7.5 (24.6)
Drain Hose
Inner Diameter mm 16 16
Length mm 650 650
Indoor Heat Exchanger
Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 15 x 21 2 x 15 x 21
Size (W x H x L) mm 810 x 315 x 25.4 810 x 315 x 25.4
Outdoor Heat Exchanger
Fin Material Aluminium (Blue Coat) Aluminium (Blue Coat)
Fin Type Slit Fin Slit Fin
Row x Stage x FPI 2 x 34 x 17 2 x 34 x 17
Size (W x H x L) mm 25.4 x 714 x 806.2
826.2
25.4 x 714 x 806.2
826.2
Air Filter
Material Polypropelene Polypropelene
Type One-touch One-touch
Power Supply Indoor Indoor
Power Supply Cord A — —
Thermostat — Mechanical
Protection Device 2 Stage Overload Protector Inner Protector
Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Indoor Operation Range
Maximum32233223
Minimum16111611
Outdoor Operation Range
Maximum43264326
Minimum16111611
MODEL INDOOR CS-C18JKV CS-C24JKV
OUTDOOR CU-C18JKV CU-C24JKV