12.13. Patrol Operation
To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation.
Patrol operation start condition
- When the unit operation is started with “OFF/ON” button.
- When the unit stops, “Patrol” button is pressed, Patrol individual operation will start.
- During cooling only operation, “Patrol” button is pressed.
Patrol operation stop condition (when any of the following condition is fulfilled):
- When “OFF/ON” button is pressed.
- During any operation with Patrol, "Patrol" button is pressed again.
- When “e-ion” button is pressed.
- When OFF Timer activates.
Patrol operation disable
- To disable the Patrol Operation during unit start (default) with “OFF/ON” button, press “Patrol” button and hold for 5
seconds, then release.
- To disable the Patrol Operation, press “Patrol” button and hold for 15 seconds, then release.