43 
12.4  Indoor Fan Speed Control 
  Indoor fan speed can be set using remote control. 
12.4.1  Fan Speed Rotation Chart 
Fan Speed (rpm)   
Speed 
CS-C7MKP-7 CS-C9MKP-7 CS-C12MKP-7 CS-C18MKP-7 CS-C24MKP-7 
Shi  1050 1170 1150 1390 1500 
Hi  960  1150 1120 1240 1350 
Me 860 950 940 1120 1230 
HLo 820 820 840 1090 1190 
CLo 760 760 810 1010 1110 
Lo-  700 700 760 850 970 
SLo  680 680 740 670 750 
Qhi  890  1080 1030 1150 1260 
QMe 770 860 870 1030 1140 
QLo  690 690 730 920 1020 
12.4.2  Automatic Fan Speed Control 
  When set to Auto Fan Speed, the fan speed is adjusted between maximum and minimum setting as shown in the 
table. 
o  Fan speed rotates in the range of Hi and Me (For CS-C7MKP-7, CS-C9MKP-7 and CS-C12MKP-7). 
o  Fan speed rotates in the range of Hi, Me and Lo- (For CS-C18MKP-7 and CS-C24MKP-7). 
o  Deodorizing Control will be activated. 
 
For CS-C7MKP-7, CS-C9MKP-7 and CS-C12MKP-7 
 
   SHi  Hi  Me HLo CLo Lo- SLo 
Variable 
rpm 
Stop 
Hi    o               
Me      o             
Manual 
Lo          o         
Normal 
Auto    o  o      o    o  o 
QHi   
Hi-
70 
             
QMe     
Me-
70 
           
Manual 
QLo         
CLo-
70 
       
Quiet 
Auto   
Hi-
70 
Me-
70 
    o    o  o 
Manual  o                 
Cooling 
Powerful 
Auto  o                 
Manual            o      o 
Normal 
Auto            o      o 
Manual            o      o 
Quiet 
Auto            o      o 
Manual            o      o 
Soft Dry 
Powerful 
Auto            o      o