12.13 Patrol Operation 
 
  To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation  
 
  Patrol operation starts condition 
o  When the unit operation is started with “OFF/ON” button 
o  When the unit stops, “Patrol” operation is selected, Patrol individual operation will start. 
o  During cooling only operation, “Patrol” operation is selected. 
 
  Patrol operation stops condition (when any of the following condition is fulfilled): 
o  When “OFF/ON” button is selected. 
o  During any operation with Patrol, “PATROL/e-ion” button is pressed. 
o  When OFF Timer activates. 
 
  To disable the Patrol Operation during unit starts (default) with “OFF/ON” button 
o  Press “Set” button continuously for 15 seconds by using pointer during Air Conditioner is OFF condition to 
enter internal setting mode. 
o  Press “Timer Decrement" button to select “Pt dFLt”.  
o  Press “Timer Set” button to toggle Patrol operation default OFF/ON. 
  Long "beep": Turn OFF Patrol operation default. 
  Short "beep": Turn ON Patrol operation default. 
 
SET
SET
Transmit Patrol default OFF/ON code
(Buzzer: OFF:Long Beep, ON:Short Beep)
Press continously for 15s
SET
Transmit Patrol demo code
(Buzzer: OFF:Long Beep, ON:Short Beep)
SET
Transmit ECO demo code
(Buzzer: OFF:Long Beep, ON:Short Beep)
SET
Transmit check code
(Buzzer:Short Beep)