EasyManua.ls Logo

Panasonic CS-CE9LKE - Page 45

Panasonic CS-CE9LKE
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
F97 Compressor
overheating protection
3 times happen
within 30 minutes
Compressor overheat Insufficient refrigerant
F98 Total running current
protection
3 times happen
within 20 minutes
Total current protection Check refrigeration system
Power source or compressor lock
F99 Outdoor direct current
(DC) peak detection
Continuous
happen for 7 times
Power transistor module
current protection
Power transistor module faulty or
compressor lock
Abnormality /
Protection control
Abnormality
Judgement
Protection
operation
Problem Check location
Diagnosis
display

Related product manuals