17.2. Sensible Capacity Chart
CU-CE9LKE
CU-CE12LKE
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 2.48 1.88 0.50 2.32 1.80 0.54 2.16 1.73 0.57 1.96 1.65 0.62
19.0°C 2.50 0.55
19.5°C 2.72 1.97 0.51 2.55 1.89 0.55 2.37 1.82 0.59 2.15 1.73 0.63
22.0°C 2.97 2.04 0.52 2.77 1.96 0.56 2.58 1.89 0.60 2.35 1.81 0.64
230V Outdoor Temp. (°C)
Indoor wet
bulb temp.
30 35 40 46
TC SHC IP TC SHC IP TC SHC IP TC SHC IP
17.0°C 3.47 2.63 0.87 3.24 2.52 0.94 3.02 2.43 1.00 2.74 2.30 1.08
19.0°C 3.50 0.95
19.5°C 3.81 2.76 0.89 3.56 2.65 0.95 3.31 2.55 1.02 3.01 2.43 1.10
22.0°C 4.15 2.86 0.90 3.88 2.75 0.97 3.61 2.65 1.04 3.28 2.53 1.12
TC
SHC
IP
-
-
-
Total Cooling Capacity (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Indoor 27°C/19°C
Outdoor 35°C/24°C