EasyManua.ls Logo

Panasonic CS-CZ25WKE - Page 74

Panasonic CS-CZ25WKE
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
74
To limit set temperature range for COOL & DRY, HEAT mode.
o Press “Set” button by using pointer.
o Press TEMP increment or decrement button to choose No. 3.
o Press Timer increment or decrement button to select desired temperature low limit of set temperature for
COOL & DRY mode.
Memorize new
Low2 range
Normal display mode
Press SW to enter customer zone &
Press SW’s to choose function 3
Press SW to comfirm selection
Use SW or SW to change Low2 range
SET
i) Display latest set temp (Low2).
ii) After reset, Low2 = 16°C (by default)
Range = 16°C ~ [High2]
No code transmission
o Press Timer Set button to confirm low limit selection.
o Press TEMP increment or decrement button to choose No. 4.
o Press Timer decrement or increment button to select desired temperature high limit of set temperature for
COOL & DRY mode.
Memorize new
Normal display mode
Press SW to enter customer zone &
Press SW’s to choose function 4
Press SW to comfirm selection
Use SW or SW to change High2 range
SET
i) Display latest set temp (High2).
ii) After reset, High2 = 30°C (by default)
Range = [Low2] ~ 30°C
No code transmission
High2 range
o Press Timer Set button to confirm high limit selection.

Table of Contents

Other manuals for Panasonic CS-CZ25WKE

Related product manuals