119
19. Technical Data
Technical data provided are based on the air conditioner running under free frequency.
19.1 Cool Mode Performance Data
Unit setting: Standard piping length, Hi Fan, Cool mode at 16°C
Voltage: 230V
19.1.1 CS-CZ25WKE/CU-CZ25WKE
Indoor (°C) Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 2699 2458 298 2536 2338 406 2500 2219 535
22.0 3012 1861 283 2793 1771 397 2454 1624 529
23
15.7 2563 2389 313 2372 2301 413 2114 2072 534
18.4 2775 1896 303 2527 1759 408 2269 1645 534
20
13.3 1830 1794 180 1742 1707 299 1656 1622 469
15.8 1844 1573 166 2278 1705 410 2032 1594 531
(Dry bulb value based on 46% humidity)
19.1.2 CS-CZ35WKE/CU-CZ35WKE
Indoor (°C) Outdoor DB (°C)
DB WB
16 25 35
TC SHC IP TC SHC IP TC SHC IP
27
19.0 3778 2818 521 3550 2680 710 3500 2543 935
22.0 4217 2133 494 3910 2030 694 3436 1861 925
23
15.7 3588 2738 546 3321 2637 722 2960 2511 933
18.4 3885 2173 530 3537 2016 713 3177 1885 933
20
13.3 2259 1935 235 2439 2248 522 2318 2172 820
15.8 2274 1626 222 3189 1954 717 2845 1827 928
(Dry bulb value based on 46% humidity)
TC - Total Cooling Capacity (W)
SHC - Sensible Heat Capacity (W)
IP - Input Power (W)