16.4.24 F95 (Cooling High Pressure Abnormality)
Malfunction Decision Conditions
During operation of cooling, when outdoor unit heat exchanger high temperature data (61°C) is detected by the
outdoor pipe temperature sensor.
Malfunction Caused
Air short circuit at indoor unit
Dust accumulation on the indoor unit heat exchanger
2/3 way valve closed
Faulty outdoor unit fan motor
Excessive refrigerant
Clogged expansion valve or strainer
Faulty outdoor pipe temperature sensor
Faulty outdoor unit PCB
Troubleshooting

Table of Contents

Other manuals for Panasonic CS-E12NKEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E12NKEW and is the answer not in the manual?

Panasonic CS-E12NKEW Specifications

General IconGeneral
TypeAir conditioner indoor unit
Built-in displayNo
Remotely operatedYes
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)3500 W
Heating capacity in watts (max)4400 W
Cooling energy efficiency (EER, W/W)3.87
Heating energy efficiency (COP, W/W)4.04
Indoor unit typeWall-mountable
Indoor units quantity1
Outdoor units quantity0
Noise level (low speed)20 dB
Noise level (high speed)42 dB
Noise level (medium speed)28 dB
Power requirementsAC 230 V
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)870 x 214 x 290 mm

Related product manuals