58
13.3. Remote Control Button
13.3.1. SET BUTTON
To check current remote control transmission code
- Press for more than 10 seconds.
To change the air quality sensor sensitivity
- Press and release with pointer.
- Press the Timer Decrement button to select sensitivity:
1. Low Sensitivity
2. Standard (Default)
3. Hi Sensitivity
- Confirm setting by pressing Timer Set button, a “Beep” sound will be heard. LCD returns to original display after 2 seconds.
- LCD returns to original display if remote control does not operate for 30 seconds.
13.3.2. CLOCK BUTTON
To change the remote control’s time format
- Press for more than 5 seconds.
13.3.3. RESET (RC)
To clear and restore the remote control setting to factory default
- Press once to clear the memory.
13.3.4. RESET (AC)
To restore the unit’s setting to factory default
- Press once to restore the unit’s setting.
13.3.5. TIMER
To change indoor unit indicator’s LED intensity
- Press continuously for 5 seconds.
13.3.6. TIMER
To change remote control display from Degree Celsius to Degree Fahrenheit.
- Press continuously for 10 seconds.
Remote Control Printed Circuit Board
Jumper A (J-A) Jumper B (J-B) Remote Control No.
Short Open A (Default)
Open Open B
Short Short C
Open Short D

Other manuals for Panasonic CS-E15GKEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E15GKEW and is the answer not in the manual?

Panasonic CS-E15GKEW Specifications

General IconGeneral
BrandPanasonic
ModelCS-E15GKEW
CategoryAir Conditioner
LanguageEnglish

Related product manuals