EasyManuals Logo

Panasonic CS-E15LKEW Service Manual

Panasonic CS-E15LKEW
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #72 background imageLoading...
Page #72 background image
72
Patrol Sensor Control
- First 2 minutes from Patrol function activates is stabilization time, during stabilization time, no air dirtiness level is monitored.
The Air Dirtiness level is set to Clean.
- After that, Patrol sensor starts to record the resistance value at fixed interval. Higher resistance value indicates cleaner air.
- The air dirtiness level is monitored by comparing the current resistance value with maximum resistance value from time to
time to get the Air Dirtiness Value.
- There are 3 air dirtiness level, based on the Air Dirtiness Value:
- Air Dirtiness level 0: Clean
- Air Dirtiness level 1: Moderate
- Air Dirtiness level 2: Contaminated
Dirtiness level sensitivity adjustment
It is possible to change the Patrol sensor sensitivity, where the Threshold value (G1 ~ G4) will be shifted accordingly:
1. Press and release “SET” button.
2. Press Timer / Timer button to select sensitivity. (Air 1 “Low Sensitivity Air 2 “Standard” (Default) Air 3 “High
Sensitivity”)
3. Confirm setting by pressing “Timer Set” button. LCD returned to original display after 2 seconds.
4. LCD returned to original display if remote control does not operate for 30 seconds.
e-ion Control
- e-ion operation starts condition
- When dirtiness at level 2.
- 2 minutes after stabilization time.
- 4 hours at level 0.
- e-ion operation time
- If dirtiness level improves from level 2 to level 1, the unit carries out level change after 60 seconds.
- When dirtiness level returns to level 0 continuously for 11 minutes or more, e-ion operation stops.
Dirtiness Level and fan speed
- When e-ion operation starts, the fan speed increases based on dirtiness level:
- Indoor Fan Control
- During any operation mode combines with Patrol operation, fan speed follows respective operation mode.
- During Patrol individual operation if e-ion starts, only Auto Fan Speed and no Powerful operation is allowed. Even if “Fan
Speed” button is pressed, no signal is sent to air conditioner, and no change on LCD display.
- During Patrol individual operation if e-ion stops, Indoor Fan stop operation.
Airflow direction (Horizontal, Vertical) Control
- During any operation mode combines with Patrol operation, airflow direction follows respective operation mode.
- During Patrol individual operation if e-ion starts, only Auto Air Swing is allowed. Even if “Air Swing” button is pressed, no
signal is sent to air conditioner, and no change on LCD display.
- During Patrol individual operation if e-ion stops, Airflow direction louver closed.

Table of Contents

Other manuals for Panasonic CS-E15LKEW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-E15LKEW and is the answer not in the manual?

Panasonic CS-E15LKEW Specifications

General IconGeneral
Thermostat range- °C
Hose length (max)15 m
Remotely operatedYes
Cooling capacity (max)3610 BTU/h
Dehumidifying capacity2.4 l/h
Heating capacity (max)4640 BTU/h
Cooling capacity in watts (max)4200 W
Heating capacity in watts (max)5400 W
Cooling energy efficiency (EER, W/W)3.44
Heating energy efficiency (COP, W/W)3.68
Indoor unit typeWall-mountable
Airflow750 m³/h
Noise level59 dB
Power requirements230 V
Weight and Dimensions IconWeight and Dimensions
Weight9000 g
Dimensions (WxDxH)780 x 204 x 290 mm

Related product manuals