Table (a): Auto Operation Mode Setting
Mode Shift: Temperature Shift (°C)
Cooling/Soft Dry Heating
-2.0
Heating Cooling/Soft Dry
+2.0
Table (b): Outdoor Air Temperature Shifting
Mode: Outdoor Temperature, X (°C): Temperature Shift (°C)
Manual Operation Auto Operation
Cooling/Soft Dry
38 X
1.50 2.00
30 X 38
1.25 1.25
23 X 30
1.25 1.25
X 23
1.75 1.75
Heating
21 X
-2.25 -1.50
17 X 21
-1.75 -1.00
13 X 17
-0.75 0.00
9 X 13
0.25 0.25
5 X 9
1.25 1.00
1 X 5
0.75 1.00
-3 X 1
1.50 1.00
X -3
1.50 1.00
Table (c): Powerful Mode Shifting