– 17 –
MAC9509078C2
CS-G93KE
Once the operation starts, the remote control setting temperature will be shifted internally based on the setting fan
speed and outdoor air temperature. In addition, if Sleep Mode or Powerful Mode are set, the temperature shift will
be carried out.
Setting of Internal Setting Temperature
The internal setting temperature can be decided as follows:
Remote control setting temperature
+
Outdoor temperature shift (refer Table a)
+
Fan speed shift (+ 1.0 °C)
+
Any Sleep Mode shift operation?
+
Any Powerful Operation shift? (refer Table b)
+
[Check upper/lower (33°C/16°C) limit for setting temperature]
↓
INTERNAL SETTING TEMPERATURE
Operation Details
A. FUNCTIONS
1. TEMPERATURE SHIFT
Table a
Setting Temperature Shift based on outdoor air temperature.
(i) Cooling, Soft Dry (ii) Heating
Shift amount
21°C ≤ Outdoor air temperature
17°C ≤ Outdoor air temperature <21°C
13°C ≤ Outdoor air temperature <17°C
9°C ≤ Outdoor air temperature <13°C
5°C ≤ Outdoor air temperature < 9°C
1°C ≤ Outdoor air temperature < 5°C
–3°C ≤ Outdoor air temperature < 1°C
Outdoor air temperature <–3°C
Shift amount
–1.5°C
–1.0°C
–1.0°C
0.0°C
+0.5°C
+1.0°C
+1.0°C
+1.5°C
38°C ≤ Outdoor air temperature
30°C ≤ Outdoor air temperature < 38°C
23°C ≤ Outdoor air temperature < 30°C
Outdoor air temperature < 23°C
CS-
G93KE
CS-
G123KE
–1.0°C
–0.5°C
0.0°C
+1.0°C
–1.0°C
–1.0°C
0.0°C
+1.0°C
Powerful
Cooling
–4.0°C
Dry
–3.0°C
Heating
+6.0°C
Table b
Powerful Mode Shift.
Untitled-3 6/20/00, 5:03 PM17