4. HEATING OPERATION
A. Room Temperature Control
• During heating operation, the room temperature control depends on intake air temperature and internal
setting temperature. Basically it can be divided into 2 periods as shown below:
Stabilized
period
Transition
period
Intake air temp. – internal setting temp.
–1.5°C
0°C
(i) When indoor fan speed is Medium or above.
CS-G93KE
+1.5
+1.0
+0.5
0
–0.5
–1.0
–1.5
Heating Operation
Remote Control Setting Temp.
Intake air temperature –
Internal setting temperature
Compressor OFF
Internal setting temp.
Outdoor air temperature
Stabilized Period
21°C ~ 30°C
16°C ~ 20°C
Transition Period
16°C ~ 30°C
Comp Off
15
15
22
46
53
64
71 (Fh) or
99 (Fhmax)
Comp Off
15
15
22
26
33
36
71 (Fh) or
99 (Fhmax)
–1°C and
above
Comp Off
15
26
33
36
46
53
71 (Fh) or
99 (Fhmax)
Less than
–1°C
Comp Off
15
15
22
26
33
36
71 (Fh) or
99 (Fhmax)
–1°C and
above
Comp Off
15
15
22
26
33
36
71 (Fh) or
99 (Fhmax)
Less than
–1°C
Compressor Operation Frequency (Hz)