EasyManua.ls Logo

Panasonic CS-G93KE - Installation Information; SELECT THE BEST LOCATION

Panasonic CS-G93KE
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 48 –
MAC9509078C2
CS-G93KE
No.
1
2
3
4
5
Accessories part
Installation plate
Installation plate fixing screw
Remote control
Battery
Air purifying filter
INDOOR UNIT
Qty.
1
6
1
2
2
No.
6
7
8
9
Qty.
1
1
3
1
Installation Information
Attached accessories
Accessories: Flaring piping kit
CZ-3F5, 7AEN (CS-G93KE)
CZ-4F5, 7AEN (CS-G123KE)
SELECT THE BEST LOCATION
There should not be any heat source or steam near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
Indoor unit of this room air conditioner shall be installed on the wall in a height of at least 2.3 m.
There should not be any animal or plant which could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
Do not place any obstacles which may cause a short circuit of the discharged air.
OUTDOOR UNIT
MODEL
G93KE
G123KE
Piping size
Gas
3/8"
1/2"
Liquid
1/4"
1/4"
Rated
Length
5
5
Max.
Elevation
(m)
5
5
Max.
Piping
Length
(m)
7
7
Accessories part
Drain elbow
Band
Vinyl tape
Vinyl tape
Untitled-7 6/20/00, 5:15 PM48