– 49 –
CS-G93KE
POWER SLEEP TIMER
ECONOMY
POWERFUL
Installation Information
Indoor / Outdoor unit installation diagram
Length of power supply cord Piping direction Attention not to bend up drain hose
about 1.1 m
about 1.8 m
Right
rear
Right bottom
Left
rear
Left bottom
Left
(Front side)
Right
Installation parts you must
purchase (*)
Bend the pipe as closely on the
wall as possible, but be careful
that it doesn’t break.
Saddle (*)
This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Additional drain hose (*)
Carry out installation
after checking for gas
leaks.
After securing with
three of the vinyl
tape 8, wrap with
vinyl tape 9.
Air purifying filter 5
(Left and right are identical)
Vinyl tape 8
Vinyl tape
9
5 cm
or more
5 cm
or more
10 cm
or more
10 cm
or more
100 cm
or more
1/4" Liquid side piping (*)
Gas side piping (*)
3/8" (G93KE)
1/2" (G123KE)
Connecting cable
(4-CORE WIRE/1.5 mm
2
)
Locally approved cable.
Insulation of piping connections
Installation plate 1
Bushing-Sleeve (*)
Sleeve (*)
Putty, (Gum Type Sealer) (*)
Vinyl tape (Wide) (*)
Apply after carrying out a
drainage test.
To carry out the drainage
test, remove into the heat
exchanger. To carry out the
drainage test, remove into
the heat exchanger.
<
<
<
<
Untitled-7 6/20/00, 5:15 PM49