– 19 –
MAC9509078C2
CS-G93KE
Operation Details
B. Deodorizing Control
• This control is available during automatic fan speed for Cooling and Soft Dry Operation. It is not available
during anti-freezing control.
• When the compressor is in operation, the deodorizing status starts from 1 → 2 → 3.
• When the compressor stops operation, the deodorizing status starts from 4 → 5 → 6 → 7.
• If the compressor still stops operation after 3 minutes, the deodorizing status will start from 6.
C. Sensible Heat Control
• This control is to improve the feeling in high fan speed during low operation frequency. When the operation
frequency is less than 33Hz (CU-G93KE) or 36Hz (CU-G123KE), the fan speed will reduce. When the
operation frequency is increased to 40Hz (CU-G93KE) or 49Hz (CU-G123KE) continuously for 5 minutes,
the fan speed will resume to normal condition.
Indoor
Fan Speed
Compressor
ON
Deodorizing Status
Compressor
ON OFF
Time (second)
Indoor Fan Speed
1
40
OFF
2
50
SLo
3
Auto
4
30
SLo
5
60
OFF
6
30
SLo
7
60
OFF
6, 7, 6, 7,…
………
………
ON
1
40
OFF
ON
OFF
OFF
Untitled-3 6/20/00, 5:03 PM19