Compressor frequency is set at 40Hz (CU-G93KE) or 49Hz (CU-G123KE) when the deice operation starting signal is
generated.
30 seconds later deice operation starting signal is generated, indoor fan, outdoor fan, 4-way valve are turned off and
compressor operates at 40Hz (CU-G93KE) or 49Hz (CU-G123KE) for 30 seconds. (Deice operation starts)
During deice operation, the compressor operating frequency is set at 58Hz (CU-G93KE) or 83Hz (CU-G123KE).
Deice will end when the outdoor heat exchanger temperature rises to 16°C or after 11 minutes.
Deice Operation Time Chart
Operation Details
Compressor operating
frequency
58Hz (CU-G93KE)
83Hz (CU-G123KE)
40Hz (CU-G93KE)
49Hz (CU-G123KE)
Indoor Fan
Outdoor Fan
4-way valve
Outdoor Heat
Exchanger
Temperature (°C)
Free
ON
ON
ON
OFF
OFF
OFF
OFF
99Hz
(CU-G93KE)
115Hz
(CU-G123KE)
Hot Start
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
16
–6
–7
–9
–11
Deice
Operation
Starting
Signal
Deice Operation
Ending
Signal
Deice max 11 min
Heating
Operation
Heating
Operation
30 sec30 sec
30
sec