Operation Details
(a) Cooling Automatic Fan Speed
The Automatic Fan Speed for cooling operation is shown as below:
(i) When Automatic Fan Speed is selected
10
sec.
a
Fan No. 15
Fan No. 13
Fan No. 11
b
cde
f
ghab
80 sec.
10
sec.
a
Fan No. 17
Fan No. 15
Fan No. 13
b
cde
f
ghab
80 sec.
(ii) When Automatic Fan Speed and Powerful Mode are selected
Note: The Fan Speed will change every 10 seconds and it will be repeated from a to h every 80
seconds.
(b) Heating Automatic Fan Speed
The Automatic Fan Speed for heating operation is shown below:
When Automatic Fan Speed is selected, the Fan Speed will change every 10 seconds from Fan
Speed No. 7 to No. 15 depending on indoor heat exchanger temperature. Each time the Fan Speed
will move 1 rank up or down.
When Automatic Fan Speed and Powerful Mode are selected, the Fan Speed will change for every
10 seconds from Fan Speed No. 11 to No. 27 depend on heat exchanger temperature. Each time
the Fan Speed will move 1 rank up or down.
Operation Details
Outdoor fan motor is controlled with 1 speed only. Fan is in operation when the compressor starts operation
and stops 30 seconds after compressor stops operation.
(c) Cooling Operation at SHi Speed
During Cooling operation, Indoor Fan speed is set at SHi when the following conditions occur:
Outside air temperature is 30°C or above
Compressor operates at 50Hz (CU-G93KE) or 70Hz (CU-G123KE) and above
Remote control setting fan speed is High
Indoor intake air temperature is 24°C or above
Remote control setting temperature is 16°C
Within 30 minutes after start of operation.
(d) Heating Operation at SSHi Speed
During Heating operation, Indoor Fan speed is set at SSHi when the following conditions occur:
Heating operation for 2 hours or more
When remote control setting fan speed is High
Indoor intake air temperature is 17°C or above and less than 23°C
Outdoor air temperature is below 4°C
Remote control setting temperature is 30°C
Compressor operates at 71Hz (CU-G93KE) or 90Hz (CU-G123KE) and above
Airflow Direction is set at Manual.
– 34 –
MAC9609040C2
– 35 –
MAC9609040C2
ON
ON
ON
ON
OFF
OFF
Compressor
Outdoor Fan
30
sec
8. OUTDOOR FAN CONTROL