– 40 –
MAC9509078C2
CS-G93KE
Operation Details
(b) Heating Operation
When the sleep button is pressed, the remote control setting temperature will decrease 2°C after 1 hour or
when the remote control setting temperature is reached. After another hour, 3°C will be decreased again.
* During sleep shift operation, indoor fan speed operates at Lo
.
max 1 hour
8 hours
All stop
1 hour
Remote control
setting temperature
When Sleep
button is pressed
Sleep mode shift
operation starts
–3°C
–2°C
When the Delay On Timer is set by using remote control, the unit will start to operate slightly earlier before the
set time, so that the room will nearly reach the set temperature by the On Timer set time.
60 minutes before the set time, the indoor fan operates at Lo
and outdoor fan operates for 20 seconds to sense
the indoor intake air temperature and outdoor air temperature in order to determine the starting time for
preparatory operation. (The Power LED blinks during sampling.)
The time of the preparatory operation will start before the On Timer set time.
a. Cooling/Soft Dry b. Heating
13. DELAY ON TIMER CONTROL
If there is a power failure, operation will automatically be restarted when the power is resumed from 2 minutes
58 seconds to 3 minutes 52 seconds randomly. It will start with the previous operation mode and airflow direction.
Auto Restart Control is not available when Timer or Sleep Mode is set.
J1 at indoor electronic controller should be open circuit when cancellation of Auto Restart Control.
14. AUTO RESTART CONTROL
5 min
10 min
25
30
Outdoor air temp.
Indoor
intake
air temp
(°C)
35 (°C)
30
15 min
45 min
35 min
5
0
Outdoor air temp.
Indoor
intake
air temp
(°C)
5(°C)
15
25 min
Untitled-5 6/20/00, 5:11 PM40