The useful wiring error check function automatically corrects
wiring errors using a microcomputer.
In cases where wires are embedded or the locations of
connecting wires are not known for other reasons, for instance,
pressing the wiring error check switch inside the right side
panel of the outdoor unit enables operation as is even if the
wires to room A are connected to room B by mistake. Wiring
error checks cannot be performed in the following situations:
·
For about 30 seconds (during the initial settings) after the
power was turned on
·
During the 3-minute standby after the compressor has
stopped
·
When the outside air temperature is below 5 °C
·
When trouble has occurred in the indoor unit (including
trouble in transmission to all rooms)
This function need not be used if the correct piping and
wiring are completely done.
Operation method
1. Remove the service panel (right side panel). (5 screws)
2. Press the writing error check switch on the service
monitor P.C. Board to start the writing error check
operation.
3. The writing error check is automatically completed in
about 10 to 15 minutes.
4. When the faulty wiring check is completed, the service
monitor LEDs blink.
LED 1 2 3 4 Judgement
Display All LEDs
blink
Blinking Automatic Correction cannot
be done.
Blink in
sequence
Off Automatic Correction have
been implemented.
Automatic correction have been implemented: LEDs 1, 2 and 3
blink in sequence (LED4 is off).
Automatic correction cannot be done: LEDs 1 to 4 blink
simultaneously to indicate:
·
A transmission problem in one of the indoor units
·
A disconnected heat exchanger thermistor in an indoor unit
·
Trouble in an indoor unit (when the trouble has occurred
during the wiring error check)
Trouble stopping: One of the LEDs 1 to 4 lights.
Precautions
1. About 10 to 15 minutes are required to conduct the
check after the wiring error switch is pressed.
(Only wiring error between an unit A and unit B cannot
be corrected.)
2. If liquid pipes and gas pipe connected to different unit it
cannot be corrected "automatically", be absolutely sure
to run the liquid pipes and gas pipes in pairs.
3. If the wiring error check switch is pressed again during
a wiring error check, the wiring error check can be
forcibly terminated. In this case, what is stored in the
microcomputer will be the initial statuses (wiring room A
piping A port, wiring room B piping B port).
4. The wiring error check function MUST be used when
the outdoor unit P.C. Board is replaced.
Basic knowledge
·
The principle operation of this function is as follows: The
refrigerant flows in succession from the port A, and by
detecting the temperature of the indoor unit heat
exchanger sensor, the connected pipes and wires are
collated.
·
The sound of ice forming (a crackling noise) may be
heard from the indoor unit while this function is
operating: this is normal and not indicative of a
malfunction. (This phenomenon occurs because the
heat exchanger temperature is lowered to 0 °C or below
in order to improve the detection accuracy.)
·
The indoor fan is also set to ON and OFF at the same
time.
How to check the information currently stored in the
microcomputer
This information can be checked by observing the blinking
of the LEDs on the service monitor upon completion of the
wiring error check, during forced operation or after stopped.
LED1: Wiring room A, LED2: wiring room B
The first LED to blink denotes the piping port A and the
second LED denotes the piping port B.
The LED which has lighted first denotes the room whose
wiring is connected to the piping port A, and the next LED
denotes the port B.
<Example> When the LEDs blink as shown below
The LEDs in this figure denote that the piping port A has
been connected (automatically corrected) to the wiring
room B and that the piping port B has been connected
(automatically corrected) to the wiring room A.
9.3.4. Wiring Error Check Control
48
CS-ME7CKPG / CS-ME10CKPG / CS-ME12CKPG / CS-ME14CKPG / CS-ME18CKPG / CU-2E15CBPG / CU-2E18CBPG / CU-3E23CBPG / CU-4E27CBPG

Table of Contents

Other manuals for Panasonic CS-ME12CKPG

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-ME12CKPG and is the answer not in the manual?

Panasonic CS-ME12CKPG Specifications

General IconGeneral
BrandPanasonic
ModelCS-ME12CKPG
CategoryAir Conditioner
LanguageEnglish

Related product manuals