ENGLISH
11
Accessories
● This air conditioner consists of 1 outdoor unit linked up
with 2 or more indoor units.
● It is definitely possible to operate with 1 indoor unit. It is
also possible to operate 2 or more indoor units at the
same time.
● When 2 or more indoor units are in operation, the
efficiency will be lower as compared to that of 1 unit in
operation.
● Sometimes, certain types of operating modes may not
operate under different circumstances.
HEATING
HEATING ✕
COOLING OR DRY
✕
AIR CIRCULATION
OPERATING
MODE
OPER-
ATING MODE
: Possible to operate 2 or more indoor units at the
same time.
✕ : Subsequent to the selection of this combination, only
the operating indoor unit will not operate. (The
operation lamp of the non-operative indoor unit will
blink) Please select once more the operating mode
that you wish to stop.
: Only the indoor unit that has “heating” operating
mode selected will operate. The unit that has “Air
Circulation” operating mode selected will not
operate.
(The operation lamp of the non-operative indoor unit
will blink)
■ COMBINATION OF OPERATING
MODES
REMOTE
CONTROL
HOLDER 2 pcs
of installation
screws
(Page 8)
AAA size alkaline
batteries (2 pcs)
(Page 9)
Catechin air purifying filter
Solar refreshing deodorizing filter
COOLING
OR
DRY
AIR
CIRCULA-
TION
COOLING
COOLING
COOLING
HEATING
HEATING
AIR CIRCULATION
■ NOTES
● If the unit is not going to be used for an
extended period of time, turn off the main
Power supply. If it is left at the ON position,
approximately 2.5 W of electricity will be used
even if the indoor unit has been turned off with
the remote control.
● If operation is stopped, then restart
immediately, the unit will resume operation
only after 3 minutes.
Use under the
following conditions (Unit in°C)
DBT:
Dry Bulb Temp
Cooling Heating
Indoor Outdoor Indoor Outdoor
WBT:
Wet Bulb Temp
DBT WBT DBT WBT DBT WBT DBT WBT
Maximum
Temperature
32 23 43 26 30 – 24 18
Minimum
Temperature
16 11 16 11 16 – -5 -6
MULTI air conditioner function