37
12.2.2. CLOCK
To change the remote control’s clock-hour and minute.
- Press once to enter the clock setting mode.
- Use timer increment button timer decrement button to change the time.
- Press once again to exit the setting mode.
To change the time format (24 hours & 12 hours timer display).
- Press for more than 5 seconds.
12.2.3. RESET
To clear and restore the remote control setting to factory default.
- Press for once to clear the memory.
12.2.4. TIMER “
Press continuously for 5 seconds, LED intensity for Remote Control dimmer code is transmitted.
Above condition will not happen when Timer is set.
12.2.5. TIMER “
Press continuously for 10 seconds, set the operation and display changes as Celsius or Fahrenheit.
Above condition will not happen when Timer is set.
12.3. Test Mode Timer Table
Test Mode
Name Time (When test point Remarks
Short-circuited)
1 hr. 1 min.
Real Timer 10 min. 10 sec.
1 min. 1 sec.
Timer Delay Safety Control 2 min. 58 sec. 0 sec.
Forced Operation 60 sec. 0 sec.
Timer Save Control 7 min. 4.2 sec.
Anti-Freezing 4 min. 0 sec.
Auto Mode Judgement 20 sec. 0 sec.
Soft Dry OFF 6 min. 36 sec.
ON 10 min. 60 sec. Soft Dry: 10 min. operation
Cooling 40 sec. 4 sec.
70 sec. 7 sec.
Deodorizing Control 20 sec. 2 sec.
180 sec. 18 sec.
Soft Dry 40 sec. 4 sec.
360 sec. 36 sec.
Comp. Reverse Rotation Detection 5 min. 30 sec. Com. ON 5 min. and above
2 min. 0 sec.
Comp./ Fan Motor Delay Timer 1.6 sec. 0 sec.
Random Auto Restart Control 0 ~ 62 sec. 0 ~ 6.2 sec.