1.AUTO Operation Switch
2.Indoor Unit Indicator
7.2. Operation and Display of Indoor Unit
AUTO Operation
1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.
2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.
3. When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.
4. When the switch is pressed between 11 to 16 seconds and together with the signal from the remote controller, the unit can
be changed to different controlling setting (A-B).
5. When the switch is pressed between 16 to 21 seconds, either H14 error detection selection mode or remote controller’s
signal receiving sound can be cancelled or turned on.
6. If the intake air temperature is less than 16°C and the Forced Cooling is activated, because the prior operation mode is
heating, the compressor will stop for 3 minutes to start the Forced Cooling operation.
ON OFF FLASH
Operation
(Green)
Run Stop Hot start, deice control,mode
judging and ON TimerOperation
detecting.
Timer
(Orange)
Timer set Timer not set Malfunction happens.
19
CS-PE9CKE / CU-PE9CKE / CS-PE12CKE / CU-PE12CKE