7.7. Automatic Operation
If the Auto operation mode is selected, the operation mode will be judged by set temperature on remote control, intake air
temperature and outdoor air temperature.
During operating mode judgement, indoor fan runs at low fan speed and outdoor fan runs in the purpose of detecting the intake
air temperature and outdoor air temperature (for 20 seconds)
Set Temp on
Remote Control
16, 17, 18 +10 -3 -5
19, 20, 21, 22 +8 -3 -7
23, 24, 25, 26 +7 -3 -7
27, 28, 29, 30 +6 -3 -8
If the operation mode changed, , , will change as follow:
Cooling /Soft Dry
→
Heating Operation: -2°C
Heating
→
Cooling /Soft Dry Operation: +2°C
45