14.4.18 F93 (Compressor Rotation Failure)
Malfunction Decision Conditions
A compressor rotation failure is detected by checking the compressor running condition through the position
detection circuit.
Malfunction Caused
Compressor terminal disconnect
Outdoor PCB malfunction
Troubleshooting
Normal?
When F93 indication ha
pp
ens
For safety reason and to prevent component
breakdown, always switch off the power
before remove and connect the component.
Turn off power supply. Disconnect U, V
and W wires
IPM defective
Replace outdoor unit PCB
NO
YES
Check with inverter checker.
Replace compressor