82
Cooling Characteristic at Different Piping Length
Condition
Indoor room temperature: 27/19°C, 35/-°C
Remote control setting: HI FAN, COOL 16°C
Compressor frequency: F
c
6.500
6.600
6.700
6.800
6.900
3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
Piping Length (m)
Cooling
Capacity (kW)
9.640
9.660
9.680
9.700
9.720
9.740
9.760
3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
Piping Length (m)
Current
(A)
0.830
0.840
0.850
0.860
0.870
0.880
35791113151719212325272931
Piping Length (m)
Gas Side Piping
Pressure (MPa
)
12.600
12.700
12.800
12.900
13.000
3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
Piping Length (m)
Outlet Air
Temperature (°C
)
230