Heating Characteristic at Different Outdoor Air Temperature
Condition
Indoor room temperature: 20/-°C
Remote control setting: HI FAN, HEAT 30°C
Compressor frequency: F
h
34.000
36.000
38.000
40.000
42.000
44.000
46.000
-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10
Outdoor Air Temperature (°C)
Outlet Air
Tempeature (°C
)
230
5.700
6.200
6.700
7.200
7.700
8.200
8.700
9.200
9.700
-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10
Outdoor Air Temperature (°C)
Heating
Capacity (kW)
9.300
9.800
10.300
10.800
11.300
11.800
12.300
12.800
13.300
-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10
Outdoor Air Temperature (°C)
Current
(A)
2.300
2.500
2.700
2.900
3.100
3.300
3.500
-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7 8 9 10
Outdoor Air Temperature (°C)
Gas Side Piping
Pressure (MPa
)