12.3.5 Automatic Restart Control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to
four minutes after power supply resumes.
12.3.6 Indication Panel
LED POWER TIMER
Color Green Orange
Light ON Operation ON Timer setting ON
Light OFF Operation OFF Timer setting OFF
Note:
● If POWER LED blinks, the possible operation of the unit is operating mode judgment, or ON timer
sampling.
● If Timer LED blinks, there is an abnormal operation occurs.
12.3.7 Timer control
Delay ON Timer can be set using remote controller, the unit with timer set will start operate earlier than the setting
time. This is to provide a comfortable environment when reaching the set On time. Seventy minutes before the set
time for ON Timer or ON-OFF Timer setting, indoor ( at fan speed of Lo-) and outdoor fan motor start operate for 30