52 
• e-ion Check Mode 
o  e-ion abnormality check mode 
o  Purpose is to improve sensor serviceability when sensor is malfunction. 
(1)  Control starting condition 
When all of the conditions are formed 
•  Not in Patrol Demo mode. 
•  e-ion operation ON. 
•  When e-ion check mode signal is received; the procedure of selection is as shown: 
o  Press “Set” button continuously for 15 seconds by using pointer to enter internal setting mode. 
o  Press “Timer Decrement" button to select “CHC”. 
o  Confirm setting by pressing “Timer Set” button, a “beep” sound will be heard. 
 
 
o  If abnormal discharge is detected at filter (short-circuited) due to water or dust adhesion, etc., the e-ion 
indicator blinks immediately. 
 
•  Error Detection Control 
When e-ion indicator blink, it indicates error listed below: 
o  Active e-ion Air Purifying system PCB main connector open: 
 Judgment Method 
•  During e-ion operation (include during Patrol operation), Active e-ion Air Purifying system main 
connector to PCB is opened. 
 
 Troubleshooting Methods 
•  Connect the connector or stop operation (include during Patrol operation) to cancel the blinking. 
 
o  Abnormal Discharge error: 
 Judgment Method 
•  During e-ion operation, feedback voltage is-Lo (at microcontroller) is detected, it is judged abnormal 
discharge and stops power supplies to the Active e-ion Air Purifying system. 
•  Abnormal discharge is caused by ionizer or filter’s high voltage power supply short-circuits due to 
water or dust adhesion, and so forth. 
•  When abnormal discharge occurred, every 30 minutes the unit supplies power to the Active e-ion Air 
Purifying system. 
•  When abnormal discharge occurs for 24 times continuously, e-ion indicator blinks (not applicable for 
e-ion Check Mode, where the error will shows immediately despite the 24 times counter)