Indoor CS-TE20TKEW CS-TE25TKEW
Outdoor CU-TE20TKE CU-TE25TKE
Performance Test Condition EUROVENT EUROVENT
Power Supply
Phase, Hz Single, 50 Single, 50
V 230 230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW 0.75 2.00 2.40 0.85 2.50 3.00
BTU/h 2560 6820 8180 2900 8530 10200
Kcal/h 650 1720 2060 730 2150 2580
Running Current A – 2.40 – – 3.00 –
Input Power W 250 530 640 250 670 910
Annual Consumption kWh – 265 – – 335 –
EER
W/W 3.00 3.77 3.75 3.40 3.73 3.30
BTU/hW 10.24 12.87 12.78 11.60 12.73 11.21
Kcal/hW 2.60 3.25 3.22 2.92 3.21 2.84
ErP
Pdesign kW 2.0 2.5
SEER (W/W) 6.1 6.1
Annual
Consumption
kWh 115 143
Class A++ A++
Power Factor % – 96 – – 97 –
Indoor Noise (H / L / QLo)
dB-A 37 / 25 / 20 40 / 26 / 20
Power Level dB 53 / 41 / 36 56 / 42 / 36
Outdoor Noise (H / L / QLo)
dB-A 46 / – / – 47 / – / –
Power Level dB 61 / – / – 62 / – / –
Heating
Capacity
kW 0.70 2.70 3.60 0.80 3.30 4.10
BTU/h 2390 9210 12300 2730 11300 14000
Kcal/h 600 2320 3100 690 2840 3530
Running Current A – 3.05 – – 3.60 –
Input Power W 185 680 1.05k 195 810 1.15k
COP
W/W 3.78 3.97 3.43 4.10 4.07 3.57
BTU/hW 12.92 13.54 11.71 14.00 13.95 12.17
Kcal/hW 3.24 3.41 2.95 3.54 3.51 3.07
ErP
Pdesign kW 1.9 2.4
Tbivalent °C -10 -10
SCOP (W/W) 4.0 4.1
Annual
Consumption
kWh 665 820
Class A+ A+
Power Factor % – 97 – – 98 –
Indoor Noise (H / L / QLo)
dB-A 38 / 26 / 22 40 / 27 / 22
Power Level dB 54 / 42 / 38 56 / 43 / 38
Outdoor Noise (H / L / QLo)
dB-A 47 / – / – 48 / – / –
Power Level dB 62 / – / – 63 / – / –
Low Temp. : Capacity (kW) / I.Power (W) / COP 2.61 / 930 / 2.81 2.97 / 1.02k / 2.91
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 2.14 / 870 / 2.46 2.70 / 1.07k / 2.52
Max Current (A) / Max Input Power (W) 4.7 / 1.05k 5.1 / 1.15k
Starting Current (A) 3.05 3.60