B
Brittney CurrySep 2, 2025
What causes the water flowing sound in Panasonic CS-TE35TKEW during operation?
- CCarol HancockSep 3, 2025
The water flowing sound during operation is due to the refrigerant flow inside the unit.
What causes the water flowing sound in Panasonic CS-TE35TKEW during operation?
The water flowing sound during operation is due to the refrigerant flow inside the unit.
Why does mist emerge from my Panasonic CS-TE35TKEW indoor unit?
The mist emerging from the indoor unit is a condensation effect due to the cooling process.
Why is my Panasonic CS-TE35TKEW Air Conditioner making a cracking sound during operation?
The cracking sound during operation is caused by changes in temperature that lead to the expansion and contraction of the unit's components.
Why does the POWER indicator blink on my Panasonic CS-TE35TKEW before it turns on?
The POWER indicator on your Panasonic Air Conditioner might blink before the unit is switched on as a preliminary step in preparation for operation when the ON timer has been set. When the ON Timer is set, the unit may start earlier (up to 35 minutes) before the actual set time in order to achieve the desired temperature on time.
Why is the cooling/heating capacity reduced on my Panasonic CS-TE35TKEW Air Conditioner at the lowest fan speed?
If you've noticed a reduction in cooling/heating capacity during the lowest fan speed setting on your Panasonic Air Conditioner, it's because the low fan speed prioritizes low noise operation, which can reduce cooling/heating capacity. To increase capacity, increase the fan speed.
Why Panasonic Air Conditioner unit doesn't receive signal from remote control?
If your Panasonic Air Conditioner unit isn't receiving the signal from the remote control, ensure that the receiver is not obstructed. Note that certain fluorescent lights may interfere with the signal transmitter; consult an authorized dealer for assistance.
How to reduce noise during Panasonic CS-TE35TKEW operation?
If your Panasonic Air Conditioner is noisy during operation, check whether the unit has been installed at an incline and ensure that the front panel is properly closed.
Why does my Panasonic CS-TE35TKEW Air Conditioner outdoor unit emit water or steam?
The outdoor unit emits water or steam because condensation or evaporation occurs on the pipes.
Why is the TIMER indicator always on in my Panasonic CS-TE35TKEW?
The TIMER indicator is always on because the timer setting repeats daily once set.
What to do if Panasonic Air Conditioner remote control does not work?
If your Panasonic Air Conditioner unit isn't responding to the remote control, first ensure the batteries are correctly inserted or replace them if they are weak.
Type | Air conditioner indoor unit |
---|---|
Multi-split | No |
Product color | White |
Inverter technology | Yes |
Timer duration (maximum) | 24 h |
Air conditioner functions | Cooling, Heating |
Heating capacity in watts (max) | 5100 W |
Heating capacity in watts (min) | 800 W |
Cooling capacity in watts (nominal) | - W |
Seasonal efficiency rating (cooling) (SEER) | - |
Heating capacity in watts (nominal) (Average heating season) | 4000 W |
Seasonal efficiency rating (heating) (SCOP) (Average heating season) | 4.1 |
Airflow | 708 m³/h |
AC input voltage | 230 V |
Design load (cooling) | 3.5 kW |
Energy efficiency class (cooling) | A++ |
Annual energy consumption (cooling) | 201 kWh |
Hourly energy consumption (cooling) | - kWh |
Design load (heating) (Warmer heating season) | - kW |
Design load (heating) (Average heating season) | 2.8 kW |
Annual energy consumption (heating) (Average heating season) | 956 kWh |
Indoor unit type | Wall-mountable |
Indoor unit depth | 290 mm |
Indoor unit width | 799 mm |
Indoor unit height | 197 mm |
Indoor unit weight | 8000 g |
Indoor units quantity | 1 |
Heating airflow (indoor unit) | 750 m³/h |
Indoor unit noise level (high speed) | 58 dB |
Outdoor unit noise level | - dB |