8.4.7. Anti-Dew Formation Control
Purpose is to prevent dew formation on indoor unit air discharge area.
When room temperature is constant (±1°C) the following conditions occur for 30 minutes continuously, anti-dew formation will
activate:
Remote Control setting temperature is less than 25°C.
Compressor is on.
Cooling operation mode.
Indoor Fan motor operate at Low fan speed (CLo, Lo- or QLo).
This control is cancelled immediately when above condition is changed, or Powerful button is pressed.
Anti-Dew formation is control by:
1. CLo fan is changed to HLo fan.
2. QLo fan is changed to HLo fan.
8.5. Indoor Fan Speed Control
Indoor Fan Speed can be set using remote control.
8.5.1. Fan Speed Rotation Chart
Fan Speed (rpm) CS-V7DKE CS-V9DKE CS-V12DKE
SHi 1140 1250 1310
Hi 1050 1140 1280
Me 900 940 1080
HLo 850 840 960
CLo 780 750 870
Lo- 750 750 850
SLo 710 710 820
SS Lo - - -
QSHi - - -
QHi 950 1040 1180
QMe 800 840 980
QHLo - - -
QLo 680 650 770