EasyManua.ls Logo

Panasonic CS-V7DKE - Horizontal Airflow Direction Control; Powerful Operation; Quiet Operation

Panasonic CS-V7DKE
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When the vertical airflow direction is set to Manual using the
remote control, the automatic airflow is released and the
airflow direction louver move up and down in the range
shown in the diagram.
The louver can be adjusted by pressing the button to the
desired louver position.
When stop operation using the remote control, the
discharge vent is reset, and stop at the closing position.
During Anti-dew condensation prevention, Airflow Direction
Manual control angle change from 10°,15°,20°,26°,32° to
22°,24°,26°,28°,30° under Cooling and Soft Dry operation
mode.
Cooling and Soft Dry Operation
8.7.2. Manual Control
8.8. Horizontal Airflow Direction Control
The horizontal airflow direction louvers can be adjusted manually by hand.
8.9. Powerful Operation
The Powerful operation is to achieve the setting temperature quickly.
When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the present
setting temperature (Lower temperature limit: 16°C).
This operation automatically will be running under SHi Fan Speed (Cooling).
Vertical Airflow Direction:-
-InManual setting, the vane will automatically shift down 10° lower than previous.
-InAuto setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
Powerful operation stops when:-
Powerful operation has operate for 15 minutes.
Powerful button is pressed again.
Quiet button is pressed.
Stopped by OFF/ON operation button.
Timer OFF activates.
Operating mode is changed.
8.10. Quiet Operation
The Quiet operation is to provide quiet cooling operation condition compare to normal operation.
(Cooling and Soft Dry Operation condition)
Once the Quiet Mode is set at the remote control, Quiet Mode LED illuminates. The sound level will reduce either around
2 dB(A) for Lo fan speed or 3 dB(A) for Hi/Me fan speed against the present sound level operation.
Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo
+ 80 rpm). After that, it goes back to QLo+160 (However Quiet LED remains on).
25
CS-V7DKE CU-V7DKE / CS-V9DKE CU-V9DKE / CS-V12DKE CU-V12DKE

Table of Contents

Other manuals for Panasonic CS-V7DKE

Related product manuals